- 比利時(shí)StuvEX防爆與防火設(shè)備
- 美國(guó)RCS腐蝕產(chǎn)品監(jiān)測(cè)設(shè)備
- 盧森堡ROTAREX羅達(dá)萊克斯滅火系...
- 意大利GM SISTEMI火花探測(cè)及...
- 西班牙ADIX安迪克斯抑制爆炸系統(tǒng)
- 備盈倍BS&B防爆**系統(tǒng)
- 賀爾碧格Newson Gale防爆靜...
- 賀爾碧格hoerbiger防爆**系...
- 意大利Aircom愛(ài)科粉塵防爆設(shè)備
- 法國(guó)Stif斯緹福粉塵防爆設(shè)備
- 西班牙Adix安迪克斯隔爆閥抑制系統(tǒng)...
- 瑞士Rico瑞科爆炸隔離閥
- 意大利Control logic康洛...
- 意大利Control logic康洛...
- 意大利科恩除塵和防爆產(chǎn)品
- 美國(guó)Argus火花和金屬探測(cè)以及回收...
- 美國(guó)Edwards愛(ài)德華消防報(bào)警系統(tǒng)
- 美國(guó)Kidde凱德廚房滅火和空氣采樣...
- 美國(guó)Marioff HI-FOG高壓...
- 挪威納斯克激光氣體分析儀
- 德國(guó)Rembe認(rèn)必泄壓爆破片及隔離塵...
- 英國(guó)Amal阻火器
- 英國(guó)Marvac呼吸閥和緊急泄放閥以...
- 英國(guó)Marston防爆板和爆破片
- 美國(guó)ZOOK防爆板
- 瑞士Rico-Ventex隔爆閥
- 德國(guó)GreCon格雷康火花探測(cè)器以及...
- 德國(guó)Eltex埃爾特克斯防爆靜電接地...
- 美國(guó)迪康氣體檢測(cè)設(shè)備
- 美國(guó)PAC實(shí)驗(yàn)室和在線(xiàn)分析儀器
- 奧德姆/安姆特儀器產(chǎn)品
- 美盛環(huán)境監(jiān)測(cè)行業(yè)成套系統(tǒng)工程
- 美盛流體污染控制,過(guò)濾,分離凈化產(chǎn)品
- 美國(guó)Norman不銹鋼高壓過(guò)濾器
- 美國(guó)施羅德過(guò)濾器以及過(guò)濾系統(tǒng)
- 韓國(guó)杜科給水設(shè)備以及泵系統(tǒng)
- 美國(guó)Cameron卡麥龍過(guò)程控制和閥...
- 美國(guó)BARTON測(cè)量?jī)x器儀表
- 美國(guó)NUFLO儀表產(chǎn)品
- 美國(guó)clif mock采樣設(shè)備和系統(tǒng)
- Caldon超聲波技術(shù)產(chǎn)品
- 美國(guó)Cameron/Barton卡麥...
- 美國(guó)Pentail濱特爾油液凈化設(shè)備...
- 韓國(guó)雷尊泰克REZONTECH火焰探...
- 韓國(guó)CSA Bestouch火焰探測(cè)...
- 科馬特泰克色譜技術(shù)產(chǎn)品
- 英國(guó)愛(ài)丁堡Edinburgh ins...
- 歐美Cerex/AquaRead等進(jìn)...
- 歐文凱利自控閥設(shè)備
- 德?tīng)柛馜raeger**檢測(cè)設(shè)備
- 美國(guó)Det-tronics火焰探測(cè)器...
- 泵閥控制
- 美國(guó)Honeywell生命**產(chǎn)品
- 密析爾濕度和露點(diǎn)儀表
- 美國(guó)TIF公司鹵素檢漏儀
- 美國(guó)Teledyne Analyti...
- 美國(guó)泰科SCOTT健康和**
- 日本日置HIOKI電測(cè)產(chǎn)品
- 英國(guó)梅克羅尼(MICRONICS)超...
- 美國(guó)AII氧分析儀
9502系列二氧化碳監(jiān)控功能的新一代紅外感應(yīng)器,重新定義了紅外氣體遙感科學(xué)。結(jié)構(gòu)緊湊,易于使用9502系列二氧化碳監(jiān)視器需求控制在暖通空調(diào)通風(fēng),環(huán)境室,室內(nèi)空氣質(zhì)量,溫室監(jiān)控,以及許多其他商業(yè)和工業(yè)應(yīng)用等應(yīng)
.jpg)
The Series 9502 Carbon Dioxide Monitor features a next generation infrared sensor that redefines the science of infrared gas sensing. The compact and easy to use Series 9502 CO2 Monitor is suitable for applications in HVAC Demand Control Ventilation, Environmental Chambers, Indoor Air Quality, Greenhouse Monitoring, and many other commercial and industrial applications.
-
Features and Benefits
-
System Description
-
Specifications
-
Download PDF Data Sheet
(Requires Adobe Acrobat Reader) -
Contact Us
Features | Benefits |
Non-dispersive IR Sensor |
Exceptional Reliability |
Factory Calibrated |
Ensures Accurate Readings from the Start |
Sturdy ABS Case |
Handles the Rigors of Industrial Applications |
Isolated Power Supply |
Eliminates Ground Loop Problems |
Large LCD Display |
Easy to Read from Distance as well as Angles |
Adjustable Alarm Relay |
Alert Personnel of Unacceptable CO2 Levels |
System Description
The Series 9502 CO2 Monitor features a next generation infrared sensor that redefines the science of infrared gas sensing. The compact and easy to use Series 9502 CO2 Monitor is suitable for applications in HVAC Demand Control Ventilation, Environmental Chambers, Indoor Air Quality, Greenhouse Monitoring, and many other commercial and industrial applications.
The non-dispersive infrared (NDIR) sensor is the focal point of the Series 9502 CO2 Monitor. Unlike electrochemical carbon dioxide sensors, non-dispersive infrared gas sensors do not chemically react with the gas being sampled. The ability of certain gases to absorb infrared radiation has been successfully utilized in developing various gas sensing instruments. A key advantage factor over traditional IR sensors is the ease in which the Series 9502 can be field calibrated. Its superior design makes field calibration fast and easy. And, because of the high reliability components used in the Series 9502 Carbon Dioxide Monitor, calibration intervals are much longer (years rather than months) than rival devices.
The Series 9502 CO2 Monitor comes equipped with an easy-to-see 0.35” high liquid crystal display, single adjustable alarm relay, and a 4-20 mADC linear output that can be used with a recorder, datalogger, etc. In addition to the 4- 20 mADC output, the Series 9502 CO2 Monitor has a 0-10 VDC analog output also. Both analog outputs can be scaled by the user over any low and high values as long as they don’t exceed the range of the monitor.
Back To Top
Specifications
Measurement Range: 0-5,000 Parts Per Million (PPM)
Measurment Error: ± 5% of reading at standard or ± 75 ppm whichever is greater stated at a temperature and pressure (250°C and 760 mm Hg)
Response Time: < 60 seconds to 90% of step change
Sensor Type: NDIR-Non Dispersive Infrared
Gas Sampling Method: Diffusion
Pressure Effect: 0.19% of reading per mm Hg
Repeatability: ± 20 ppm
Warm-up: <180 seconds
Operating Temperature Range: 0° to 50° C
Humidity Range: 0-95%, non-condensing (when in operation)
Calibration Interval: 3 years recommended with no initial customer calibration required
Power Source: 18-30 VDC, 20-28 VRMS AC. Power consumption < 2 watts @ 24 VDC
Analog Outputs: A linearized 0-10 VDC or 4- 20 mADC (RL < 500 ohms), user selectable
(analog outputs can be adjusted by user)
Relay Output: Adjustable single trip point. Rated 2A@ 24 VDC
Digital Display: 4 digit 0.35” liquid crystal display (LCD)
Warranty: Two years (expected operating life expectancy > 10 years)
Enclosure Material: ABS
Dimensions: 5.2” H x 3.2” W x1.4” D
Back To Top