- 比利時StuvEX防爆與防火設(shè)備
- 美國RCS腐蝕產(chǎn)品監(jiān)測設(shè)備
- 盧森堡ROTAREX羅達萊克斯滅火系...
- 意大利GM SISTEMI火花探測及...
- 西班牙ADIX安迪克斯抑制爆炸系統(tǒng)
- 備盈倍BS&B防爆**系統(tǒng)
- 賀爾碧格Newson Gale防爆靜...
- 賀爾碧格hoerbiger防爆**系...
- 意大利Aircom愛科粉塵防爆設(shè)備
- 法國Stif斯緹福粉塵防爆設(shè)備
- 西班牙Adix安迪克斯隔爆閥抑制系統(tǒng)...
- 瑞士Rico瑞科爆炸隔離閥
- 意大利Control logic康洛...
- 意大利Control logic康洛...
- 意大利科恩除塵和防爆產(chǎn)品
- 美國Argus火花和金屬探測以及回收...
- 美國Edwards愛德華消防報警系統(tǒng)
- 美國Kidde凱德廚房滅火和空氣采樣...
- 美國Marioff HI-FOG高壓...
- 挪威納斯克激光氣體分析儀
- 德國Rembe認必泄壓爆破片及隔離塵...
- 英國Amal阻火器
- 英國Marvac呼吸閥和緊急泄放閥以...
- 英國Marston防爆板和爆破片
- 美國ZOOK防爆板
- 瑞士Rico-Ventex隔爆閥
- 德國GreCon格雷康火花探測器以及...
- 德國Eltex埃爾特克斯防爆靜電接地...
- 美國迪康氣體檢測設(shè)備
- 美國PAC實驗室和在線分析儀器
- 奧德姆/安姆特儀器產(chǎn)品
- 美盛環(huán)境監(jiān)測行業(yè)成套系統(tǒng)工程
- 美盛流體污染控制,過濾,分離凈化產(chǎn)品
- 美國Norman不銹鋼高壓過濾器
- 美國施羅德過濾器以及過濾系統(tǒng)
- 韓國杜科給水設(shè)備以及泵系統(tǒng)
- 美國Cameron卡麥龍過程控制和閥...
- 美國BARTON測量儀器儀表
- 美國NUFLO儀表產(chǎn)品
- 美國clif mock采樣設(shè)備和系統(tǒng)
- Caldon超聲波技術(shù)產(chǎn)品
- 美國Cameron/Barton卡麥...
- 美國Pentail濱特爾油液凈化設(shè)備...
- 韓國雷尊泰克REZONTECH火焰探...
- 韓國CSA Bestouch火焰探測...
- 科馬特泰克色譜技術(shù)產(chǎn)品
- 英國愛丁堡Edinburgh ins...
- 歐美Cerex/AquaRead等進...
- 歐文凱利自控閥設(shè)備
- 德爾格Draeger**檢測設(shè)備
- 美國Det-tronics火焰探測器...
- 泵閥控制
- 美國Honeywell生命**產(chǎn)品
- 密析爾濕度和露點儀表
- 美國TIF公司鹵素檢漏儀
- 美國Teledyne Analyti...
- 美國泰科SCOTT健康和**
- 日本日置HIOKI電測產(chǎn)品
- 英國梅克羅尼(MICRONICS)超...
- 美國AII氧分析儀
示蹤氣體泄漏標準 - 也被稱為校準泄漏,泄漏標準和氦氣泄漏 - 正處于一個廣泛使用的測試應(yīng)用。下面是CTS提供的各種規(guī)格型號的描述
TP型號,可在從10-9到10-2 ATM的毫升/ s的泄漏率,主要是開發(fā)真空系統(tǒng)校準和氦氣泄漏探測器,在真空狀態(tài)下試驗。該型號采用了切斷閥,允許在不刪除從測試校準泄漏多方面你“零”的泄漏檢測器
CPV和CPS型號也可以流動的幾種不同燃氣種類或從10-5到10-2泄漏率混合ATM的毫升/秒,開發(fā)準確校準“嗅探器”型檢漏儀
該CPS型號是一個重要的工具,它允許您檢查一個組合中示蹤氣體濃度。
CPH型號可流動青山不等10-6氣體泄漏率幾種不同類型10-2 ATM的毫升/秒,這一模式是發(fā)展成為與超高真空系統(tǒng)和其他地方在毒氣和背景信號必須保持在*低限度的關(guān)鍵應(yīng)用程序兼容。這主要是開發(fā)真空系統(tǒng)真空校準和氦氣泄漏檢測器檢測,這種模式的特點是全金屬關(guān)閉不刪除從測試校準分水器閥門泄漏,讓你“零”的泄漏檢測器。
CP型號,雖然氦通常也可流動的范圍從10-6氣體泄漏率幾種不同類型10-2 ATM的毫升/秒,CP型號主要是在真空狀態(tài)下進行校準真空系統(tǒng)和氦氣泄漏檢測器檢測。該模型采用了切斷閥,允許在不刪除從測試校準泄漏多方面你“零”的泄漏檢測器
詳細部分見以下英文說明:
Tracer Gas Model Selection Overview
Tracer gas leak standards – also referred to as calibrated leaks, leak standards and helium leaks – are used in a wide variety of test applications. Below are descriptions of the various standard models offered by CTS. |
The TP model which is available in leak rates ranging from 10-9 to 10-2 atm-cc/s was primarily developed to calibrate vacuum systems and helium leak detectors that test under vacuum. This model features a shut off valve which allows you to “Zero” the leak detector without removing the calibrated leak from the test manifold. |
The CPV and CPS models are available flowing several different gas types or mixes in leak rates ranging from 10-5 to 10-2 atm-cc/s. The CPV and CPS models were developed to accurately calibrate “sniffer” type leak detectors. The CPS model is an essential tool which allows you to check the concentration of a tracer gas in a mix. |
The CPH model is available flowing several different gas types for leak rates ranging from 10-6 to 10-2 atm-cc/s. This model was developed to be compatible with Ultra-High vacuum systems and other critical applications where out gassing and background signals need to be kept to a minimum. It was primarily developed to calibrate vacuum systems and helium leak detectors that test under vacuum. This model features an all metal shut off valve which allows you to “Zero” the leak detector without removing the calibrated leak from the test manifold. |
The CP model, though typically for helium is also available flowing several different gas types for leak rates ranging from 10-6 to 10-2 atm-cc/s. The CP model was primarily developed to calibrate vacuum systems and helium leak detectors that test under vacuum. This model features a shut off valve which allows you to “Zero” the leak detector without removing the calibrated leak from the test manifold. |
The GPH model is available in leak rates ranging from 10-10 to 10-5 atm-cc/s and utilizes a reliable glass permeation type leak element. |
The GP model helium calibrated leak standard is available in leak rates ranging from 10-9 to 10-5 atm-cc/s and utilizes the same reliable glass permeation type leak element. This model features a shut off valve which allows you to “Zero” the leak detector without removing the calibrated leak from the test manifold. |