- 比利時(shí)StuvEX防爆與防火設(shè)備
- 美國(guó)RCS腐蝕產(chǎn)品監(jiān)測(cè)設(shè)備
- 盧森堡ROTAREX羅達(dá)萊克斯滅火系...
- 意大利GM SISTEMI火花探測(cè)及...
- 西班牙ADIX安迪克斯抑制爆炸系統(tǒng)
- 備盈倍BS&B防爆**系統(tǒng)
- 賀爾碧格Newson Gale防爆靜...
- 賀爾碧格hoerbiger防爆**系...
- 意大利Aircom愛(ài)科粉塵防爆設(shè)備
- 法國(guó)Stif斯緹福粉塵防爆設(shè)備
- 西班牙Adix安迪克斯隔爆閥抑制系統(tǒng)...
- 瑞士Rico瑞科爆炸隔離閥
- 意大利Control logic康洛...
- 意大利Control logic康洛...
- 意大利科恩除塵和防爆產(chǎn)品
- 美國(guó)Argus火花和金屬探測(cè)以及回收...
- 美國(guó)Edwards愛(ài)德華消防報(bào)警系統(tǒng)
- 美國(guó)Kidde凱德廚房滅火和空氣采樣...
- 美國(guó)Marioff HI-FOG高壓...
- 挪威納斯克激光氣體分析儀
- 德國(guó)Rembe認(rèn)必泄壓爆破片及隔離塵...
- 英國(guó)Amal阻火器
- 英國(guó)Marvac呼吸閥和緊急泄放閥以...
- 英國(guó)Marston防爆板和爆破片
- 美國(guó)ZOOK防爆板
- 瑞士Rico-Ventex隔爆閥
- 德國(guó)GreCon格雷康火花探測(cè)器以及...
- 德國(guó)Eltex埃爾特克斯防爆靜電接地...
- 美國(guó)迪康氣體檢測(cè)設(shè)備
- 美國(guó)PAC實(shí)驗(yàn)室和在線分析儀器
- 奧德姆/安姆特儀器產(chǎn)品
- 美盛環(huán)境監(jiān)測(cè)行業(yè)成套系統(tǒng)工程
- 美盛流體污染控制,過(guò)濾,分離凈化產(chǎn)品
- 美國(guó)Norman不銹鋼高壓過(guò)濾器
- 美國(guó)施羅德過(guò)濾器以及過(guò)濾系統(tǒng)
- 韓國(guó)杜科給水設(shè)備以及泵系統(tǒng)
- 美國(guó)Cameron卡麥龍過(guò)程控制和閥...
- 美國(guó)BARTON測(cè)量?jī)x器儀表
- 美國(guó)NUFLO儀表產(chǎn)品
- 美國(guó)clif mock采樣設(shè)備和系統(tǒng)
- Caldon超聲波技術(shù)產(chǎn)品
- 美國(guó)Cameron/Barton卡麥...
- 美國(guó)Pentail濱特爾油液凈化設(shè)備...
- 韓國(guó)雷尊泰克REZONTECH火焰探...
- 韓國(guó)CSA Bestouch火焰探測(cè)...
- 科馬特泰克色譜技術(shù)產(chǎn)品
- 英國(guó)愛(ài)丁堡Edinburgh ins...
- 歐美Cerex/AquaRead等進(jìn)...
- 歐文凱利自控閥設(shè)備
- 德?tīng)柛馜raeger**檢測(cè)設(shè)備
- 美國(guó)Det-tronics火焰探測(cè)器...
- 泵閥控制
- 美國(guó)Honeywell生命**產(chǎn)品
- 密析爾濕度和露點(diǎn)儀表
- 美國(guó)TIF公司鹵素檢漏儀
- 美國(guó)Teledyne Analyti...
- 美國(guó)泰科SCOTT健康和**
- 日本日置HIOKI電測(cè)產(chǎn)品
- 英國(guó)梅克羅尼(MICRONICS)超...
- 美國(guó)AII氧分析儀
1000系列監(jiān)控器是一個(gè)氧氣監(jiān)測(cè)旨在提供從缺氧環(huán)境的持續(xù)保護(hù)。缺氧的1000系列顯示器是政府實(shí)驗(yàn)室,大學(xué)和工業(yè)設(shè)施的熱門選擇,以幫助確保呼吸的空氣質(zhì)素。缺氧的1000系列顯示器的主要用途是,當(dāng)可能性是存在的,呼吸空氣中的氧氣可以通過(guò),如氮,氦,氬氣,二氧化碳等在危險(xiǎn)情況下所造成的惰性氣體管道儲(chǔ)存或流離失所的應(yīng)用
The Series 1000 Oxygen Deficiency Monitor is an oxygen monitor designed to provide continuous protection from oxygen deficient atmospheres. The Series 1000 Oxygen Deficiency Monitor is a popular choice of government labs, universities, and industrial facilities to help ensure the quality of breathing air. The Series 1000 Oxygen Deficiency Monitor’s primary use is for applications when the possibility exists that breathing air oxygen could be displaced by stored or piped inert gases such as nitrogen, helium, argon, carbon dioxide, etc. resulting in a hazardous condition.
- Features and Benefits
- System Description
- Specifications
- Optional Remote Sensor
- Download PDF Data Sheet
(Request Adobe Acrobat Reader) - Contact Us

Features | Benefits |
Full three-year sensor warranty |
Ensures trouble-free and cost-effective operation when compared to sensors having 6-12 month warranties |
Exceptional speed of response |
Detects oxygen alarm events in seconds |
Patented extended life oxygen sensor |
Eliminates frequent sensor replacement and annoying false low-oxygen alarms. Won’t fail due to heat fatigue like certain high temperature current limited zirconium oxide sensors. |
Economically priced |
Saves hundreds of dollars per point |
WATCHMAN CIRCUIT™ |
Alerts users of major status changes in the Series 1000 Oxygen Deficiency Monitor and the environment |
CO2 resistant sensor |
Eliminates sample conditioning and premature sensor failures, while minimizing routine maintenance |
Extended life sensor with an expected life of five years |
Be aware of high temperature current limited zirconium oxide sensors that can prematurely fail due to heat fatigue. |
Open sensor diffuser |
No dependence on a sample pump or aspirator |
System Description
The Series 1000 Oxygen Deficiency Monitor is a microprocessor-controlled instrument with a range of 0-30%. It is powered from 110/230VAC, 50-60Hz, or 18-32VDC. Battery backup is optional. Oxygen values are displayed on an easy-to-read, 10.2 mm (0.4") high, 4-1/2 digit liquid crystal display (LCD). The Series 1000 Oxygen Deficiency Monitor can be equipped with an optional remote sensor enclosure. The oxygen sensor is mounted in a resilient, polycarbonate electronics enclosure. An optional remote sensor enclosure is available for mounting up to several thousand feet from the monitor. In its standard configuration, the electronics enclosure is rated NEMA 1 (IP 30).
The eloquence of the Series 1000 Oxygen Deficiency Monitor is its ease of use. The electronics and optional remote sensor enclosures are equipped with mounting holes molded into each of the four corners for quick and easy installation. The front panel of the Series 1000 Oxygen Deficiency Monitor contains five switches that provide access to the instrument's settings. The Series 1000 Oxygen Deficiency Monitor is equipped with three oxygen alarm relays and one status alarm relay. All four relays are Form C (SPDT) types rated at 10 amps at 110/220VAC and 30VDC.The relays are user configurable for fail-safe operation. In addition to the four alarm contacts, the Series 1000 Oxygen Deficiency Monitor has a built-in audible alarm and three red LEDs for visual indication of an oxygen alarm condition. The audible alarm may be manually canceled at any time. If the audible alarm is canceled and the alarm event continues, indications of this condition will still be available through the front panel LEDs and the relay contact(s).
The Series 1000 Oxygen Deficiency Monitor comes equipped with two standard analog outputs: 4-20mADC and 0-2VDC for use with recorders, dataloggers, etc. For enhanced communications, the Series 1000 Oxygen Deficiency Monitor can also be configured with optional RS-232C or RS-485 serial communications. For multiple point installations, the RS-485 format provides the capability to send digital signals over greater distances and to control each monitor using the same communications channel.
The sensor in the Series 1000 Oxygen Deficiency Monitor has an open diffuser design and does not require a sample pump or aspiration system. Since the extended life sensor is sealed, it does not require an initial charge of electrolyte, or a periodic "topping off" due to evaporation, as do other types of oxygen sensors. Users do not have to handle caustic electrolyte (a hazardous substance).
Back To Top
Specifications
Measurement Range: 0-30% Oxygen
Accuracy: ±1% of full scale
Sensor Type: Extended Life Ambient Temperature Electrochemical Type
Temperature & Pressure Compensation: Standard
Response Time: 90% of full scale response in less than 12 seconds
Sensor Inputs: One
Product Warranty: Three years-includes both sensor and electronics
Sensor Mounting: Either in the electronics enclosure or remotely
Display: 10.2 mm (0.4") high, 4-1/2 digit liquid crystal display. Resolution 0.1% O2
Input Power: 110/230VAC, 50-60Hz or 18-32VDC. Battery backup is optional
Standard Outputs: 4-20mADC and 0-2VDC
Optional Outputs: RS-232C or RS-485
Audible Alarm: Internal buzzer.
Audible Alarm Cancel: Front panel.
Oxygen Alarm Relays: Three (3) SPDT Form C contacts rated 10 A @30VDC/110/220VAC. Alarm clearing is user selectable for either manual or automatic.
Instrument Status Alarm: 1 SPDT Form C rated identical to above.
Operating Temperature: 5° to 38°C (40° to 100°F).
Electronics Control Unit: Light gray polycarbonate with a hinged clear front cover. Rated NEMA 1 (IP 30).
-
239.8 mm (9.44 in.) length
-
159.8 mm (6.29 in.) width
-
89.9 mm (3.54 in.) height
Optional Remote Sensor Enclosure: Light gray polycarbonate rated NEMA 1 (IP 30).
Remote Sensor Enclosure Dimensions:-
119.9 mm (4.72 in.) length
-
79.8 mm (3.14 in.) width
-
84.8 mm (3.34 in.) height
Weight (Control Unit): 4.08 kg. (9 lbs.)
(Remote Sensor): <0.45 kg (<1 lb)
¹ Alpha Omega Instruments Corp. reserves the right to change or modify its product specifications without notice.
Back To TopOptional Remote Sensor
Shown above is the Series 1000 Oxygen Deficiency Monitor with optional remote sensor and audible/visual alarm. In this configuration, the sensor can be mounted several thousand feet from the electronics with both audible and visual alarm capabilities available at both the electronics and remote sensor.Back To Top -